Description
AFs filters are designed for applications in paint industry. Quantity of substances that could cause impairments in paint wetting applications or cause defects in paint work have been reduced to a minimum. To meet the required compressed air quality appropriate “paint compatible” filter element must be installed into filter housing.
Characteristics
Operating Pressure | 16 bar |
Volume Flow Rate | 60 – 2760 Nm³/h |
Connections | 3/8″ – 3″ |
Operating Temp. Range | 1,5 – 65 °C |
Standard Colour | RAL 3020 |
Applications
- Painting
- Automotive Industry
Technical Data
Filter Housing Size |
Pipe Size | Flow Rate | Dimensions |
||||||
inch | Nm³/h | scfm | A | B | C | D | |||
AFs 0056 | 3/8 | 60 | 35 | 187 | 88 | 20 | 60 | ||
AFs 0076 | 1/2 | 75 | 46 | 187 | 88 | 20 | 60 | ||
AFs 0106 | 3/4 | 120 | 70 | 257 | 88 | 20 | 80 | ||
AFs 0186 | 1 | 198 | 116 | 263 | 125 | 32 | 100 | ||
AFs 0306 | 1 | 335 | 197 | 363 | 125 | 32 | 120 | ||
AFs 0476 | 1 1/2 | 510 | 300 | 461 | 125 | 32 | 140 | ||
AFs 0706 | 1 1/2 | 780 | 459 | 640 | 125 | 32 | 160 | ||
AFs 0946 | 2 | 1,000 | 588 | 684 | 163 | 43 | 520 | ||
AFs 1506 | 2 | 1,500 | 882 | 935 | 163 | 43 | 770 | ||
AFs 1756 | 2 1/2 | 1,680 | 990 | 935 | 163 | 43 | 770 | ||
AFs 2006 | 3 | 2,160 | 1,270 | 795 | 240 | 59 | 630 | ||
AFs 2406 | 3 | 2,760 | 1,620 | 1,000 | 240 | 59 | 780 |
Correction Factors
Operating pressure [bar] | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
Operating pressure [psi] | 29 | 44 | 58 | 72 | 87 | 100 | 115 | 130 | 145 | 160 | 174 | 189 | 203 | 218 | 232 |
Correction factor | 0.38 | 0.5 | 0.63 | 0.75 | 0.88 | 1 | 1.13 | 1.25 | 1.38 | 1.5 | 1.63 | 1.75 | 1.88 | 2 | 2.13 |
Condensate Drain