Description
Operating Pressure: 50 bar
HPF process filters are designed for high pressure applications in process industry, where the risk for corrosion of compressed air system components is very high. Required compressed air quality according to standard ISO 8571-1 can be achieved with 9 different grades of filter elements. HPF process filter housing can be used in variety of applications. For applications not listed please contact producer or your local distributor. For oil removal, coalescing filter element must be installed and flow direction inside-out must be provided. General arrangement is bowl on the top and filter head on the bottom.
Condensate Drains:


Accessories:

Technical Data:
| Filter Housing Size | Pipe Size | Oper. Pressure | Flow rate at 7 bar(g), 20ºC | Dimensions (mm) | Mass | |||
| inch | bar | Nm³/h | scfm | A | B | C | kg | |
| HPF 010 | 1/2’’ | 50 | 150 | 88 | 243 | 121 | 76.1 | 2.5 |
| HPF 018 | 3/4’’ | 50 | 225 | 132 | 267 | 129 | 76.1 | 2.7 |
| HPF 030 | 1’’ | 50 | 315 | 185 | 286 | 143 | 88.9 | 3.4 |
| HPF 047 | 1 1/4’’ | 50 | 420 | 247 | 355 | 160 | 88.9 | 3.9 |
| HPF 070 | 1 1/2’’ | 50 | 600 | 353 | 400 | 182 | 114.3 | 5.6 |
| HPF 094 | 2’’ | 50 | 900 | 530 | 481 | 180 | 114.3 | 9.2 |
| HPF 150 | 2’’ | 50 | 1260 | 742 | 607 | 180 | 114.3 | 10.9 |
| HPF 200 | 3’’ | 50 | 2400 | 1413 | 1018 | 228 | 139.7 | 11.5 |
Correction Factor:
| Operating pressure [bar] | 7 | 20 | 30 | 40 | 50 |
| Operating pressure [psi] | 100 | 290 | 435 | 580 | 725 |
| Correction factor | 1 | 2.63 | 3.88 | 5.13 | 6.38 |
Filter Elements:
| Filter Element Type |
Flow Rate Nm³/h | Filter Housing |
| 420 | 150 | HPF 010 |
| 520 | 225 | HPF 018 |
| 525 | 315 | HPF 030 |
| 725 | 420 | HPF 047 |
| 730 | 600 | HPF 070 |
| 1030 | 900 | HPF 094 |
| 1530 | 1,260 | HPF 150 |
| 3030 | 2,400 | HPF 200 |