Description
Technical Data::
Breathing Air Plus System is specifically designed for applications where high quality breathing air and monitoring of breathing air supply are needed.
Prices are for complete set which includes 3 filter housings, 3 filter elements, 2 manual condensate drains, 1 automatic condensate drain and 1 differential pressure indicator.
Breathing Air Plus is a combination of our Breathing Air Plus 0106 breathing air filter set combined with gas concentration analysers, fitted with pressure regulator and quick couplings, all packed in a compact and robust casing.
Gas concentration analysers constantly monitor CO, CO₂ and O₂ concentrations and trigger an alarm if concentrations exceed the EN12021 and BS4275:1997 standard compliant values. In this way Breathing Air Plus can safely provide high quality breathing air for up to 5 people. Small dimensions and low weight enable the use of Breathing Air Plus in many applications as it can be transported and set up with ease.
Advantages:
- High quality breathing are for up to 5 people.
- Air quality monitoring (EN 12021, BS4275:1997)
- Compact & light weight)
Technical Data:
| Operating Pressure Range: | 0 – 16 bar (0-232 psi) |
| Operating Temperature Range: | 1,5 – 40 °C (35-104 °F) |
| Connection (Inlet/Outlet): | Inlet (Male), Outlet (Female) |
| Flow Rate (7 bar, 20°C): | 120 Nm³/h (71 scfm) |
| Quality Class – Solids: | ISO-8573-1 |
| Quality Class – Oils: | ISO-8573-1 |
| Element Type: | 14050 |
| Element S Grade: | solid & liquid particle filtration down to 0,01 µm |
| Element H² Grade: | O² removal |
| Element A²Grade: | oil particle filtration down to 0,1 µm |
| Standard Colour: | RAL 1016 |
Gas Analysers:
| Electrical Connection: | 230 VAC, 50-60 Hz |
| Power Consumption: | <10 W |
| CO Monitoring: | warning 3 ppm, alarm 5 ppm |
| CO² Monitoring: | alarms (increasing intensity) at 500 ppm /1500 ppm |
| O² Monitoring: | alarm at O² concentration <19,5% |
| Analyser Approval: | EN 50270:1999, EN 61000-6-3:2001+A11:2004, BS EN 61010-1:2001, IEC 61010-1 (2ed), AS 61610.1-2003 (Australia & New Zealand) |
| Protection Class of Sensors: | IP 65 |
| Dimensions: | 508 X 460 X 160 mm |
| Weights: | 12 kg |