Description
Technical Data:
Model Number | Flow Rate | Connections | Weight | Inlet pressure max bar g | ||
m³/h | l/min | scfm | BSP-F | (kg) | ||
AMD 3 | 21 | 350 | 12 | G ⅜” | 23 | 16 |
AMD 6 | 36 | 600 | 21 | G 1/2″ | 27 | 16 |
AMD 9 | 57 | 950 | 34 | G 1/2″ | 28 | 16 |
AMD 12 | 72 | 1,200 | 42 | G 1/2″ | 30 | 16 |
AMD 18 | 108 | 1,800 | 64 | G 1/2″ | 34 | 16 |
AMD 25 | 150 | 2,500 | 88 | G 1″ | 38 | 14 |
AMD 32 | 192 | 3,200 | 113 | G 1.1/4″ | 43 | 14 |
AMD 43 | 258 | 4,300 | 152 | G 1.1/4″ | 45 | 14 |
AMD 52 | 312 | 5,200 | 184 | G 1.1/4″ | 45 | 14 |
AMD 61 | 366 | 6,100 | 216 | G 1.1/2″ | 66 | 14 |
AMD 75 | 450 | 7,500 | 265 | G 1.1/2″ | 68 | 14 |
AMD 105 | 630 | 10,500 | 371 | G 2″ | 107 | 14 |
AMD 130 | 780 | 13,000 | 459 | G 2″ | 109 | 14 |
AMD 168 | 1,008 | 16,800 | 594 | G 2.1/2″ | 164 | 14 |
AMD 190 | 1,140 | 19,000 | 671 | G 2.1/2″ | 189 | 14 |
AMD 220 |
1,320 | 22,000 | 777 | G 2.1/2″ | 212 | 14 |
AMD (Aluminium Modular Dryers) dryers achieve excellent performance even in instances of high ambient and high inlet temperatures.
The highly efficient and ultra compact heat exchanger is able to operate effectively in ambient temperatures up to 45°C and inlet temperatures of 55°C, ensuring a reduced compressed air pressure drop.
AMD dryers are sized to match standard compressor outputs. E.g. a 15 kW (20 HP) air compressor with theoretical output of 2400 l/min at 7 bar matches the AMD 25 rated at 2500 l/min.
It is therefore unnecessary to select a larger model.
Air Compressor ↔ Dryer combination is tested and certified by FRIULAIR, within operating limits shown on technical data.